Products |
|
|
|
|
Fume Hoods |
|
|
|
|
|
GD is a pioneer in the field of Fume Hoods & Fume Extraction Systems. Constant innovation, stringent quality control and improvements in manufacturing processes ensure that Labexcel Fume Hoods are the best and undoubtedly the leader in the segment. |
|
|
|
 |
|
|
| |
|
Besides being available in a wide range of models, Labexcel Hoods are designed to offer the complete solution to laboratory ventilation concerns. Integrated components including fume hoods, blowers, ducts, electrical services, plumbing options and base cabinets combine to provide a safe, efficient fume hood system for your laboratory. |
|
|
| Principal Features of Labexcel Fume Hoods |
|
|
| Customised Fume Hoods is our area of expertise. |
|
|
|
| |
| |
 |
Removable Back Baffle |
 |
Easily accessible controls for service and electrical works |
 |
Fully illuminated workspace |
 |
Wide choice of sash arrangements |
 |
Wide choice of chemically resistant linings |
 |
Digital Face Velocity Meter with Alarm / Low Exhaust Indicator – optional feature to work with safe face velocity |
 |
Efficient louver and bypasses |
 |
Side panels can be opened for maintenance |
 |
Aerodynamic design |
 |
In-house fume hood performance testing facility as per ASHRAE 110-1995 guidelines |
 |
Customized fume hoods offered for various applications like handling radioactive material, low maintenance, highly efficient, low noise, chemical resistant poly propylene blower |
|
| |
|
| To make sure that the Fume Hoods we provide are the best among the available, especially in the context of your safety, they are tested under rigorous conditions. |
|
|
 |
|
|
| Fume Hood Testing |
|
| |
| GD is the first Indian Laboratory Furniture Manufacturer to have established a state-of-the-art testing laboratory at the factory to evaluate the fume hoods performance as per ASHRAE- 110 (American Society of Heating, Refrigerating and Air - Conditioning Engineers) test as per the AM guidelines. It is a relative and quantitative determination of the efficiency of a fume hood to capture contaminants under a set of strict conditions. |
|
|
The Test Laboratory is equipped with proper room pressurization system which generates air to be exhausted from the Fume Hoods being tested. The airflow is designed to provide turbulence free air entry at the front of the Hood. The test room has tight room envelope and precision electronic controls to maintain proper room pressurization. |
|
| All "Labexcel" Fume Hoods are type tested for their safety performance as per tests below: |
|
|
| Flow Visualisation Test |
| For low challenge, a small quantity of smoke is used for visual study of smoke flow pattern. For high challenge flow visualization, copious amounts of smoke is generated and released into the Fume Hoods. |
|
| Face Velocity Test |
| The sash is divided into grids and face velocity is measured at each grid point to analyze minimum, maximum and mean face velocity. |
|
| Gas Containment Test |
| This is a quantitative test where in a known quantity of gas is released within the Fume Hood and its leakage is measured at a stimulated breathing zone with an ultra precision Leak Meter and analysed. |
|
| Sash Movement Effect Test |
| The leakage of tracer gas is measured at rapid sash movement at the stimulated
breathing zone. |
|
| VAV Response Test |
| This is done when VAV controls are used for Fume Hood. The time required to regain the velocity at full designed velocity is measured. |
|
|
 |
| |
 |
|
ASHRAE 110 Testing
Labexcel Hoods are randomly selected from the production line and stringently tested as per ASHRAE 110 (American Society of Heating, Refrigerating and Air-Conditioning Engineers) in India's first fully integrated 'Fume Hood Testing Laboratory' within our factory. This test is a relative and quantitative determination of the efficiency of a fume hood to capture contaminants under a set of strict conditions. |
|
|
| |
|
|
|
|
|
| |
We know that different laboratories have different needs, so we have built a wide range of Fume Hoods and other safety equipment to help you choose the right fit. And if you have a typical need, we will make one which is tailor
made for you. |
|
|
| Select from a range of Labexcel Fume Hoods Models like Bench Fume Hoods, Walk-In Fume Hoods, Low-Bench Fume Hoods, Special Purpose Fume Hoods, Customised Fume Hoods of assorted sizes from widths of 750 mm up to 2400 mm and with Liners like FRP, Polypropylene and with work surfaces ranging from Fibre Glass, Stainless Steel, Plastic Sheets, Epoxy Coated Steel, Ceramic Tiles, Granite and Imported Solid Epoxy Tops. Different Fume Extraction Systems are also provided for Fume Hoods like AAV, CAV and VAV (Conventional, By-Pass Air, Restricted By-Pass and Auxiliary Air). |
| |
| |
|
|
| |
Models |
|
|
|
|
| |
|
|
|
|
|
|
| Bench Hood |
 |
|
|
| Distillation Hood |
 |
|
|
| Walk-In Type Hood |
 |
|
|
|
|
|
|
| |
Description |
|
| |
|
|
| |
| Model No. & Overall Normal Size in mm of Fume Hood (without Fume Hood base ) |
BFH 1200 (1200 x 950 x 1450) / BFH 1500 (1500 x 1050 x 1450 ) / BFH 1800 (1800 x 1050 x 1450) / BFH 2100 (1800 x 1050 x 1450) / BFH 2400 (1800 x 1050 x 1450) |
Tailor made /
Customised as per
customer requirement |
| Model No. & inside Fume hood working dimension ( in mm) |
BFH 1200 (900x650x1200) / BFH 1500 (1200 x 750 x 1200) / BFH 1800 (1500 x 750 x 1200) / BFH 2100 (1800 x 750 x 1200) / BFH 2400 (2100 x 750 x 1200) |
| Model No. & Bench Hood Base length in mm x Depth in mm x Height in mm |
BFH 1200 (1200 x 840 x 800) / BFH 1500 (1500 x 940 x 800) / BFH 1800 (1800 x 940 x 800) / BFH 2100 (2100 x 940 x 800) / BFH 2400 (2400 x 940 x 800) |
| Length in mm x depth-Sash to Baffle in mm x height in mm |
BFH 1200 (1050 x 600 x 1200) / BFH 1500 (1200 x 750 x 1200/1350) / BFH 1800 (1500 x 750 x 1200/1350) |
Tailor made /
Customised as per
customer requirement |
| Length in mm x depth-Sash to Lattice in mm x height in mm |
BFH 1200 (1050 x 500 x 1200) / BFH 1500 (1200 x 650 x 1200/1350) / BFH 1800 (1500 x 650 x 1200/1350) |
| Construction material |
External GI epoxy powder coated / SS 316 / SS 304, Internal Liners as required |
|
| Exhaust systems |
Constant Air Volume / Variable Air Volume / Auxiliary Air Supply |
| Sash configuration |
Standard Vertical Sliding / Combination of Vertical Rising and Horizontal Sliding / Auto Sash Vertical Rising / Horizontal Sliding Door for Walk-in Fume Hood |
| Liner option |
Fibre Glass Reinforced Plastic (FRP) / Stainless Steel (for Radioactive and Perchloric Acid use) / Polypropylene (PP) / Phenolic Resin |
| Work surface |
Dished Ceramic / Dished Jet Black Granite / Imported Black Epoxy Top / Raised Edge / Dished SS 316 / 304 as required |
| Drip Cup / Sink |
Flanged PP Black Drip Cup with outlet coupling of sizes - Round - 100 mm dia / 150 mm dia / 200 mm dia or Oval - 220 mm x 100 mm x 170 mm - Deep / Customised size / SS 316 Rectangular / Round / Ceramic |
| Lattice / Scaffolding |
GI - PU Coated / SS 316 / Aluminum Alloy Rods |
| Electrical Fittings |
North - West make 6/16 A Socket & 16 A MCB Switch - Qty. as per requirements / Industrial BCH Sockets & Switch / Optional - Special |
| Valves / Faucets / Services |
Remote operated Front Panel mounted - Valves - Water, Chilled Water, D.M. Water, Nitrogen, Gas, Vacuum, Compressed Air / Any other service with Spoutes / Nozzles of 90 degree / 45 degree fitted on sides of Fume Hood |
| Temperature Indicator |
Optional Range - 50 degree to + 150 degree Centigrade with RTD Sensor PT-100 |
| Face Velocity Meter |
Optional - TEL AFA 1000/1 / Equivalent Make and Model |
| Airflow Indicator |
Optional - TEL AFA 500/1 or AFA2S / Equivalent Make and Model |
| BFV |
Inbuilt - PP / GI / SS for initial manual set-up , Optional - Motorised Damper for VAV Controls |
| Blower |
Imported PP Casing & Impeller / PP-FRP Casing & Impeller / SS Casing & Impeller / Tailor made / Customised as per customer requirement |
| Colour |
Ivory / Orange / Cool Blue / Red / Green / Blue /
Munshell Grey |
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|